MiniAir60 Probe anemometer
The self-contained anemometer probe MiniAir60 measures the velocity, gaseous media and liquid, directly giving out a linear frequency signal.
Accuracy and reliability are of the high standard expected from Schiltknecht.
|
MiniAir60 Micro |
MiniAir60 Mini |
MiniAir60 Macro |
Range |
0.5 to 20m/s 0.7 to 40m/s |
0.3 to 20m/s 0.5 to 40m/s |
0.15 to 20m/s |
Accuracy |
1.0% FS, 3.0% rdg |
0.5% FS, 1.5% rdg |
0.5% FS, 1.5% rdg |
Oper’ Temperature |
-10 to +80°C |
-10 to +80°C |
-10 to +80°C |
Power |
4.5 to 5.5Vdc |
4.5 to 5.5Vdc |
4.5 to 5.5Vdc |
Current at 5Vdc |
0.5mA |
0.5mA |
0.5mA |
Output Frequency |
0-2.9kHz(20m/s) 0-2.8kHz(40m/s) |
0-1.8kHz(20m/s) 0-1.7kHz(40m/s) |
0-960Hz |
Output format at 5Vdc w.o.load |
pulse 0-4V |
pulse 0-4V |
pulse 0-4V |
TTL compatible |
Yes |
Yes |
Yes |
Head diameter |
Ø11 x 15mm |
Ø22 x 28mm |
Ø85 x 80mm |
Access opening |
16mm |
35mm |
|
Probe length |
165mm |
175mm |
225mm |
Cable |
5m |
5m |
5m |
Storage temp. |
-65 to +150°C |
-65 to +150°C |
-65 to +150°C |
|
MiniWater60 Micro |
MiniWater60 Mini |
|
Range |
0.04 to 5m/s |
0.02 to 5m/s |
|
Accuracy |
2% FS, 3.0% rdg |
2% FS, 3% rdg |
|
Oper’ Temperature |
0 to +70°C |
0 to +70°C |
|
Power |
4.5 to 5.5Vdc |
4.5 to 5.5Vdc |
|
Current at 5Vdc |
0.5mA |
0.5mA |
|
Output Frequency |
0-760Hz |
0-460Hz |
|
Output format at 5Vdc w.o.load |
pulse 0-4V |
pulse 0-4V |
|
TTL compatible |
Yes |
Yes |
|
Head diameter |
Ø11 x 15mm |
Ø22 x 28mm |
|
Access opening |
16mm |
35mm |
|
Probe length |
165mm |
175mm |
|
Cable |
5m |
5m |
|
Storage temp. |
-65 to +150°C |
-65 to +150°C |
|